§ 60.482-6. Standards: Open-ended valves or lines.
255 words·~1 min read·
/us/cfr/t40/s§ 60.482-6·A research copy — for the controlling text, always check the official state or federal source. Not legal advice.
(a)(1) Each open-ended valve or line shall be equipped with a cap, blind flange, plug, or a second valve, except as provided in § 60.482-1(c) and paragraphs
(d)and
(e)of this section.
(2)The cap, blind flange, plug, or second valve shall seal the open end at all times except during operations requiring process fluid flow through the open-ended valve or line.
(b)Each open-ended valve or line equipped with a second valve shall be operated in a manner such that the valve on the process fluid end is closed before the second valve is closed.
(c)When a double block-and-bleed system is being used, the bleed valve or line may remain open during operations that require venting the line between the block valves but shall comply with paragraph
(a)at all other times.
(d)Open-ended valves or lines in an emergency shutdown system which are designed to open automatically in the event of a process upset are exempt from the requirements of paragraphs (a),
(b)and
(c)of this section.
(e)Open-ended valves or lines containing materials which would autocatalytically polymerize or would present an explosion, serious overpressure, or other safety hazard if capped or equipped with a double block and bleed system as specified in paragraphs
(a)through
(c)of this section are exempt from the requirements of paragraphs
(a)through
(c)of this section. [48 FR 48335, Oct. 18, 1983, as amended at 49 FR 22607, May 30, 1984; 65 FR 78277, Dec. 14, 2000; 72 FR 64881, Nov. 16, 2007]
Connections39 cite this
Cited by 39 sections · top 15
CFR
- § 63.2450What are my general requirements for complying with this subpart?
- § 63.148Leak inspection provisions.
- § 63.172Standards: Closed-vent systems and control devices.
- § 63.489Batch front-end process vents—monitoring equipment.
- § 63.497Back-end process provisions—monitoring provisions for control and recovery devices used to comply with residual organic HAP limitations.
- § 63.129Transfer operations provisions—reporting and recordkeeping for performance tests and notification of compliance status.
Citation graph
cites case law
§ 60.482-6
Standards: Open-ended valves or lines.
Fed. Reg.×27
C.F.R.×12
Cites 0Cited by 39 across 2 sources